Effectiveness of The Holladay II Formula in Calculating Diopter Power of The Intraocular Lens
Keywords:
Holladay I, Holladay II, SRK-T, Hoffer Q, Residual spherical defect intraocular lens, Diopter Power of The Intraocular Lens (LIO).Abstract
Introduction: The calculation of the dioptric power of the intraocular lens is the determining factor of the postoperative refractive condition in patients, and the selection of the appropriate formula is crucial.
Objective: To evaluate the effectiveness of Holladay II formula in calculating the dioptric power of the intraocular lens.
Methods: A longitudinal comparative descriptive study was carried out, 40 eyes distributed in three groups according to the axial length were evaluated, which underwent the extraction of the lens and the implantation of the intraocular lens. These lenses were calculated with a formula chosen at random to determine the effectiveness. The residual spherical defect, the estimated spherical defect and the optimal spherical difference were evaluated three months after surgery.
Results: The Holladay II formula was effective in all axial lengths for the residual spherical defect, the Hoffer Q in the low and normal axial lengths, and the SRK-T was effective in the normal and high axial length. The Holladay II was effective at the low axial length for optimal spherical difference, less effective than the Hoffer Q at the normal axial length, and effective at the high axial length.
Conclusions: The Holladay II formula was effective in all axial lengths with a refractive defect considered Emmetropic.
Downloads
References
Jeong J, Song H, Lee JK, Chuck RS, Kwon JW. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas. BMC ophthalmology. 2017[acceso:22/06/2021];7(1):62. Disponible en: https://bmcophthalmol.biomedcentral.com/track/pdf/10.1186/s12886-017-0454-y.pdf
Ballate NEM, Jiménez PR, Sosa GI, Borges PS, Márquez FM, Díaz RA. Defectos esféricos residuales: diferencias entre el valor dióptrico del lente antes y después de la operación de catarata. Revista Acta Médica. 2017[acceso:22/06/2021];8(1):13-19. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Revista+Acta+M%C3%A9dica.+2017%3B8%281%29%3A13-19.&btnG
Mueller A, Thomas BC, Auffarth GU, Holzer MP. Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: keratometry and repeatability. Journal of Cataract & Refractive Surgery. 2016[acceso:22/06/2021];42(5):672-8. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%285%29%3A672-8.&btnG
Ronald B. Melles, Jack T Holladay, William J. Chang. Accurancy of Intraocular Lens Calculation Formulas. American Academy of Ophthalmology. 2017;8:27. DOI: http://dx.doi.org/10.1016/j.ophtha.2017
Abulafia A, Barrett GD, Koch DD, Wang L, Assia EI. Protocols for Studies of Intraocular Lens Formula Accuracy. American journal of ophthalmology. 2016[acceso:22/06/2021];164:149-50. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=50.Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%285%29%3A672-8.&btnG
Olsen T. Calculation of intraocular lens power: a review Acta Ophthalmol Scand. 2007[acceso:22/06/2021];85(5):472-85. Disponible en: https://scholar.google.es/scholar?protocols+for+Studies+of+Intraocular+Lens+Formula+Accuracy.+American+journal+of+ophthalmology.+2016%3B164%3A149-
Melles RB, Holladay JT, Chang WJ. Accuracy of Intraocular Lens Calculation Formulas. Ophthalmology. 2018[acceso:22/06/2021];125:169-78. Disponible en https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Accuracy+of+Intraocular+Lens+Calculation+Formulas.+Ophthalmology.+2018%3B125%3A169-78
Cordelette C, Arndt C, Vidal J, Afriat M, Durbant E, et al. Is Holladay 2 formula acurate enough for calculating intraocular lens power in non-standard eyes. Journal Français d’Ophtalmologie. 2018[acceso:22/06/2021];41(4):308-14. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Accuracy+of+Intraocular+Lens+Calculation+Formulas.+Ophthalmology.+2018%3B125%3A169-
Hoffer KJ, Savini G. IOL Power Calculation in Short and Long Eyes. Asia Pac J Ophthalmol (Phila). 2017[acceso:22/06/2021];6(4):330-1. Disponible en: https://scholar.google.es/scholar?review+Acta+Ophthalmol+Scand.+2007%3B85%285%29%3A472-
Aramberri J. Bases ópticas para comprender el cálculo de la lente intraocular. En: Ruiz Mesa R, Taña Rivero Pedro. Óptica para el cirujano facorrefractivo. España, Barcelona: Elsevier; 2015[acceso:22/06/2021]. pp. 391-3. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q
Cooke DL. Unexpectedly low power formula lens constants. Journal of Cataract & Refractive Surgery. 2017[acceso:22/06/2021];43(3):433. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Unexpectedly+low+power+formula+lens+constants.+Journal+of+Cataract+%26+Refractive+Surgery.+2017%3B43(3)%3A433&btnG
Jack Kane, Anton Van Heerden, Alp Atik. Intraocular lens power formula accuracy: comparison of 7 formulas Constantinos Petsoglou. Journal of Cataract and Refractive Surgery. 2016[acceso: 22/06/2021];42(10):1490-1500. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Intraocular+lens+power+formula+accuracy%3A+comparison+of+7+formulas+Constantinos+Petsoglou.+Journal+of+Cataract+and+Refractive+Surgery.+2016%3B42%2810%29%3A1490-
Evdoxia Terzi, Li Wang, Thomas Kohnen. Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia. Journal of cataract and Refractive Surgery. 2009[acceso:22/06/2021];35(7):1181-9. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Accuracy+of+modern+intraocular+lens+power+calculation+formulas+in+refractive+lens+exchange+for+high+myopia+and+high+hyperopia.+Journal+of+cataract+and+Refractive+Surgery.+2009%3B35%287%29%3A1181-
Cooke DL, Cooke TL. Comparison of 9 intraocular lens power calculation formulas. Journal of Cataract & Refractive Surgery. 2016[acceso:22/06/2021];42(8):1157-64. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Comparison+of+9+intraocular+lens+power+calculation+formulas.+Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%288%29%3A1157-64.&btnG
Hill Garg. IOL calculations: U.S. and international surgeons differ on formula preference EyeWorld news magazine 2015[Acceso: 22/06/2021]. Disponible en: https://www.eyeworld.org/article-iol-calculations--u-s--and-international-surgeons-differ-on-formula-preference
Downloads
Published
How to Cite
Issue
Section
License
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).