Pachymetry and intraocular pressure in healthy, suspected and sick patients with chronic simple glaucoma
Keywords:
glaucoma, intraocular pressure, pachymetry, central corneal thicknessAbstract
glaucoma is one of the most prevalent nosological entities and one of the main causes of blindness in the developed world. Intraocular pressure (IOP) is the only treatable risk factor and is associated with the presence and progression of the disease.
Objective: to evaluate the possible relationship between central corneal thickness and intraocular pressure.
Methods: a descriptive and prospective study was conducted between June 2009 and March 2011 in the Ophthalmology Service of "Hermanos Ameijeiras"Hospital. An ophthalmologic exam was performed to all the patients under study. Measurement of intraocular pressure was performed by the researcher using the Goldmann tonometer and central corneal thickness measurement was obtained with the Ultrasound Pachymeter (UP-1000); in both cases the average of 3 measurements was considered. Variables were analyzed using absolute numbers, percentages and averages.
Results: 184 eyes were evaluated. The female sex predominated (n=59) with a mean age of 56, 9 (SD=12.1). The average central corneal thickness was 542.91 microns, (SD=39.03). An average intraocular pressure of 16.63 mmHg (SD=2.76) by Goldmann tonometer was registered. The largest number of cases with the diagnosis of suspected glaucoma and primary open-angle glaucoma presented a minimum corneal thickness whereas in the cases of ocular hypertension, the majority of them, presented thick corneas.
Conclusions: the measurement of central corneal thickness with ultrasound pachymetry is very useful because it determines the interpretation of intraocular pressure. Its usefulness is not limited only to the selection of patients and the diagnosis, but also allows evaluating the follow-up, the response to the treatment and improves clinical results and prognosis.
Downloads
References
1. Kanski JJ. Clinical Ophthalmology. 6th. ed. International. 2007;(13):374 6.
2. Jerald A Bell, MD. Ocular Hypertension: Medicine Ophthalmology. 2008 Nov;10.
3. Jeffrey Henderer. Entendiendo los Exámenes de Campo Visual. Philadelphia, Pennsylvania: Glaucoma Service Foundation to Prevent Blindness; 2010.
4. Skuta GL, Cantor LB, Weiss JS. Glaucoma. In: Basic and clinical science course. American Academy of Ophthalmology. The Eye M.D. Association. 2008-2009;(5).
5. Piloto Díaz I, Fernández Aragonés L, Miquel Rodríguez M. Confiabilidad de la presión intraocular. 1ra. ed. La Habana: Editorial Ciencias Médicas; 2009. p. 351-62.
6. Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000;44:364-408.
7. Zambrano M. Correlación entre el espesor central de la córnea y la evolución del glaucoma. Revista Peruana de Oftalmología. 2010 Enero-Junio;33(1):10-4.
8. Hahn S, Azen S, Ying-Lai M, Varma R. Los Angeles Latino Eye Study Group. Central corneal thickness in Latinos. Invest Ophthalmol Vis Sci. 2003;44:1508-12.
9. Ríos González LC, Lima Gómez V. Detección de glaucoma: proporción de ojos que requiere corrección de presión intraocular por modificaciones del grosor corneal. Rev Mex Oftalmol. Septiembre-Octubre 2009;83(5):284-7.
10. Alías EG, Ferreras A, Polo V, Larrosa J M, Pueyo V, Honrubia FM. Importancia del espesor corneal central en el estudio de hipertensos oculares, sospechosos de glaucoma y glaucomas preperimétricos. Archivo de la Sociedad Española de Oftalmología. 2007 octubre;82:(1).
11. Alezzandrini A, Frick M, Della Savia L, López M. Estudio Comparativo de Medición del Espesor Corneal Central Utilizando Paquimetría Ultrasónica y Pentacam. Arch Oftal B. Aires. 2009;80(2):71-3.
12. Béjar Cornejo F, Olivares D, Cantero MA, Sánchez J. Grosor corneal central determinado mediante topografía corneal OBRSCAN en pacientes diagnosticados con glaucoma en población mexicana. Rev Sanid Milit Mex. Septiembre-Octubre 2007;61(5):310-9.
13. Detry-Morel M, Jamart J, Detry MB. Clinical evaluation of the Pascal dynamic contour tonometer. Cliniques Universitaires Saint Luc, UCL, Bruxelles, Belgique. J Fr Ophtalmol. 2007 Mar;30(3):260-70.
14. La Rosa FA, Gross RL, Orengo-Nania S. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol. 2001;119:23-27.
15. Gordon MO, Kass MA. The Ocular Hypertension Treatment Study: design and abseline description of the participants. Arch Ophthalmol. 1999;117(5):573-83.
16. Labrada Rodriguez YH. Evaluación de los factores de riesgo en el glaucoma primario de ángulo agudo. Revista Cubana Oftalmología. 2008 ene-jun;21(1).
17. Luna-Martínez. Relación del espesor corneal central y la variación en la presión intraocular con daño al nervio óptico en pacientes mexicanos con glaucoma. Rev Mex Oftalmol. 2009;83(4):193-6.
18. Judith Lee, Gretchyn Bailey High Eye Pressure. The British Journal of Ophthalmology; 2010 April.
19. Gilbert Lucido ME. Estudio epidemiológico de glaucoma en población mexicana. Rev Mex Oftalmol. 2010 Abril-Junio;84(2):86-90.
20. Rueda JC, Lesmes DP, Parra JC. Valores de paquimetría en personas sanas y con glaucoma en una población colombiana. UNAB. 2007;10(2).
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).