Application of the Relationship Between Nucleus Coloration, Consistency and Opacity in the Phacoemulsification of Senile Cataract
Keywords:
Keywords, phacoemulsification, nucleus coloration, nucleus consistency, nucleus opacity, senile cataract, extracapsular lens extraction.Abstract
Objective: To demonstrate the possible relationship between nucleus coloration, consistency and opacity in senile cataract as an orientation method in phacoemulsification (FACO).
Methods: The cataracts corresponding to a hundred consecutive extracapsular lens extractions were analyzed using intraoperative mydriasis. Fresh nuclei were classified as semitransparent yellow, translucent yellow, amber, and brown. According to the mechanical force used with the second instrument (chopper) used to fragment them into wedges, we define their consistency as very hard, hard, medium hard, and soft.
Results: The mean age of the patients in the cataracts studied was 69±12 (44-83) years, with an evolution time of 4±3 (0.4-10) years from the onset of the first visual symptoms. Semitransparent yellow/medium hard to soft nuclei predominated (44.83%), followed by brown/very hard (20.6%), translucent yellow/soft to medium hard (3.45%) and amber/hard (3.03%), which evidenced that there is a significant relationship between darkening and hardening of the nucleus.
Conclusions: The relationship found between darkening and hardening of the nucleus is of great importance, as long as it guides the ophthalmic surgeon in the application of the surgical technique of phacoemulsification.
Downloads
References
Bowling B. Cristalino. En: Kanski. Oftalmología clínica. Barcelona, España: Elsevier, 2016. pp. 270-87.
Harper RA, Shock JP. Cristalino. En: Vaughan y Asbury. Oftalmología general. 18 ed. España: Lange, 2012. pp. 181-90.
Saez Arregui S de, Lorente B, Mendicute J. Clasificación de las cataratas. En: Lorente R. Cirugía del cristalino. España: Sociedad Española de Oftalmología, 2008. pp.214-21.
Bernal Reyes N, Hormigo Puertas I, Arias Díaz A. Correlación de la densidad del cristalino medida por imágenes de Scheimpflug y parámetros fotodinámicos en la optimización de la facoemulsificación. Rev Mex Oftalmol. 2014[acceso:15/4/2020];88(1):32-8. Disponible en: https://www.sciencedirect.com/science/article/pii/S0187451914000171
Urrutia Breton IP, Lima Gómez V. Opacidad del cristalino de acuerdo al sistema LOCS III en una muestra hospitalaria mexicana. Rev Hop Jua Mex. 2010[acceso:15/4/2020];77(1):43-9. Disponible en: https://www.medigraphic.com/cgi-bin/new/resumen.cgi?IDARTICULO=42347
Palmero Aragón EY, Pina García MJ, León Bernal D, Cardoso Hernández C, Rodríguez Montero P, Cabeza Martínez E. Extracción de catarata mediante la técnica de facoemulsificación con implante de lente intraocular. Gac Méd Espirituana. 2017[acceso:15/4/2020];19(2). Disponible en: https://www.medigraphic.com/pdfs/espirituana/gme-2017/gme172e.pdf
Palmero Aragón EY, García Milián J, Cardoso Hernández C. Cirugía de catarata por facoemulsificación y por extracción tunelizada esclerocorneal del cristalino. Rev Infociencia. [acceso:15/4/2020];2016;20(4):17–26. Disponible en: http://www.infocienciass.cu/index.php/infociencia/article/view/258
Gonález Salinas R, Corredor Ortega C, Garza León M, Álvarez Padilla M, Serrano Ahumada AS, Rubio Tijerina F, et al. Evaluación de parámetros quirúrgicos en cataratas. Rev Mex Oftalmol. 2019[acceso:15/4/2020];93(1):19-25. Disponible en: http://creativecommons.org/licenses/by-nc-nd/4.0/
Rdez Rivero D, Martin Perera Y, Pérez Candelaria EC, Veitia Rovirosa ZA, Mendez Duque de Estrada A. Nuevas tecnologías en cirugía de catarata por facoemulsifciacion. Rev Cubana Oftmol. 2013[acceso:15/4/2020];26(1):157-69. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S086421762013000100016
García González FR, Pérez Gómez D, Novoa Sánchez E. Facofragmentación continua en la catarata senil con núcleos de diversa consistencia. Acta Med. 2013[acceso:4/5/2018];14(1). Disponible en: http://bvs.sld.cu/revistas/act/vol14_1_13/act120113.htm
Hernández Silva JR, Hernández Ramos H, Duperet Carvajal D, Ramos López M, Perera Miniet E, Hormigó Puertas I. Cirugía bilateral secuencial inmediata del cristalino porfacoemulsificación. Rev Cubana Oftalmol. 2016[acceso:15/4/2020];29(3). Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/466/html_226
Boyd B. Preparándose para la transición. En: El arte y la ciencia en la cirugía de catarata. Panamá : Highlights of ophthalmology; 2001.
Tume Jara LM, Medina Escobar D. Técnica de facoemulsificación y astigmatismo postoperatorio Hospital Alberto Sabogal Sologuren 2018-2019. [tesis]. Perú: Universidad de San Martin de Porres. 2019[acceso:20/2/2020]. Disponible en: http://www.repositorioacademico.usmp.edu.pe/bitstream/handle/usmp/4740/tu me_jlm.pdf;jsessionid=65534883178A21BE526F1D93E9CB975E?sequence=1
Boyd B. Escogiendo la técnica de faco según la dureza del núcleo. En: El arte y la ciencia en la cirugía de catarata. Panamá: Highlights of ophthalmology; 2001.
Robles Gutierrez CR, Moctezuma Davila M, Meza Velarde HA, Martinez Castrellon A, Rangel Charqueno MG. Padron Salas A, et al. Estudio comparativo entre técnicas quirúrgicas (incisiónmanual pequeña frente a facoemulsificación) para la cirugía de catarata. Rev Mex Oftalmol. 2018[acceso:15/4/2020];92(5):239-46. Disponible en: http://creativecommons.org/licenses/by-nc-nd/4.0
Rodríguez Suárez B, Duarte Iribe N, Hormigó Puertas I, Méndez Duque de Estrada AM, García Rodríguez JL, Palazuelos López ME. Calidad de vida relativa a la función visual en pacientes operados de catarata. Rev Cubana Oftalmol. 2018[acceso:15/4/2020];32(1). Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/69
Hernández Silva JR, Barroso Cruz M, Ramos López ME, Nafeh Mengual NI, Hernández Ramos He, Río Torres M. Estudio densitométrico del cristalino y su relación con el sistema LOCS III. Rev Cubana Oftalmol. 2013[acceso:20/2/2019];26(2). Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/188/html
Bernal Reyes N, Hormigo Puertas I, Arias Díaz A. Correlación de la densidad del cristalino medida por imágenes de Scheimpflug y parámetros fotodinámicos en la optimización de la facoemulsificación. Rev Mex Oftalmol]. 2014 [acceso:20/2/2019];88(1):32-8. Disponible en: https://www.sciencedirect.com/science/article/pii/S0187451914000171
Patricio MS, Almeida AC, Rodrigues MP, Guedes ME, Ferreira TB. Correlation between cataract grading by Scheimpflug imaging and phaco time in phacoemulsification using peristaltic and venturi pumps. Eur J Ophtalmol. 2013;23(6):789-92. Disponible en: PubMed:PMID:23640507
Holgueras López A, Maldonado López MJ. Estudio del deslumbramiento en personas con opacidades de medios ópticos en condiciones mesópicas. [tesis]. España: Universidad de Valladolid. 2016[acceso:15/4/2020]. Disponible en: http://uvadoc.uva.es/handle/1032
Loyola Ordoñez DA, Cabezas CE. Prevalencia de catarata y sus principales factores de riesgo asociados en pacientes atendidos en la consulta externa de oftalmología en el Hospital General San Vicente de Paul de Ibarra, entre octubre de 2016 y octubre de 2017. [tesis]. Ecuador: Pontificia Universidad Católica del Ecuador; 2018. Disponible en: http://repositorio.puce.edu.ec/handle/220000/14979
García Castiñeiras S. Fisiología del cristalino En: Lorente R, Mendicute J. Cirugía de catarata. España: Sociedad Española de Oftalmología, 2008. pp.97-117.
García Castiñeiras S. Cataratas: etiopatogenia y bioquímica. En: Lorente R, Mendicute J. Cirugia de catarata. España: Sociedad Española de Oftalmología; 2008. pp.117-39.
Tabanedh H, Thompson GM, Heywoth P, Dorey S, Woods AJ, Lynch D. Water content, lens hardeness and caaract appearance. Eye. 1994;8(1):125-9. Disponible en: PubMed:PMID:8013706
Benecie G, Zori Geber M, Sarie D, Corak M, Mandie Z. Clinical importance of the lens opacities classification system III (LOCS III) in phacoemulsification. Coll Antropol. 2005;29(Suppl1):91-4.
Al-Khateeb G, Shajari M, Vunnava K, Petermann K, Kohnen T. Impact of lens densitometry on phacoemulsification parameters and usage of ultrasound energy in femtosecond laser-assisted lens surgery. Can J Ophthalmol. 2017;52(4):331-7. PubMed:PMID: 28774512
Anglada I, Escalona JR, de la Cámara Hermoso J. Estudio comparativo entre la facoemulsificación convencional coaxial y la técnica bimanual microincisional en la cirugía de catatara. [tesis]. España: Universidad Autónoma de Barcelona. 2015[acceso:15/4/2020]. Disponible en: https://ddd.uab.cat/record/129027
Downloads
Published
How to Cite
Issue
Section
License
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).